CLI Guide

To use this object property, you must have the Chassis Configuration Administrator privilege.
cfgAlertingSourceEmailName
Table 291. Details of cfgAlertingSourceEmailName
Description Specifies the e-mail address used to send e-mail notifications when an event occurs.
Legal Values None
Default None
Examples
racadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailName
racadm config -g cfgAlerting -o cfgAlertingSourceEmailName user@home.com
Object value modified successfully.
To use this object property, you must have Chassis Configuration Administrator and Test Alert User privileges.
cfgIPv6LanNetworking
This group is used to configure the IPv6 over LAN networking capabilities.
Use this object with the config or getconfig subcommands.
To use this object property for CMC, you must have Chassis Configuration Administrator privilege.
NOTE: To apply this setting to iDRAC, use the -m option.
The following sections provide information about the objects in the cfgIPv6LanNetworking group.
cfgIPv6Enable (Read or Write)
Table 292. Details of cfgIPv6Enable
Description Enables or disables CMC IPv6 stack.
Legal Values 1 (TRUE)
0 (FALSE)
Default 0
cfgIPv6AutoConfig (Read/Write)
Table 293. Details of cfgIPv6AutoConfig
Description Enables or disables the IPv6 Auto Configuration option.
CMC Property Database Group and Object Descriptions 149