CLI Guide

cfgChassisACPowerRecoveryDisable
Table 287. Details of cfgChassisACPowerRecoveryDisable attribute
Description
If AC power recovery is disabled, the chassis is powered off after power outage is restored.
Legal Values
0 — Enable
1 — Disable
Default
0
cfgKVMInfo
This group is used to view the mapping information for the KVM.
Use this object with the config or getconfig subcommands.
To use this object property, you must have Chassis Configuration Administrator privilege.
cfgKvmEnable
Table 288. Details of cfgKvmEnable
Description Enable KVM operation for all slots
Legal Values
0 — Disable
1 — Enable
Default 1
cfgKvmMapping
Table 289. Details of cfgKvmMapping
Description Selects the server to which the KVM connects
Legal Values
1[a-d]-4[a-d]
Default 0 (Unmapped)
cfgAlerting
This group enables or disables SNMP event trap alerting and sets the event filter.
Use this object with the config or getconfig subcommands.
cfgAlertingEnable
Table 290. Details of cfgAlertingEnable
Description Enables or disables event traps on the CMC.
Legal Values 1 (true)
0 (false)
Default None
148 CMC Property Database Group and Object Descriptions