CLI Guide

Table 208. Details of cfgServerFirstBootDevice (continued)
NOTE: For a vFlash Partition to be configured as First Boot Device, it has to be
attached first. When a detached or non-existent vFlash partition or a non-standard boot
device is configured as first boot device, the following error message is displayed:
Invalid object value
Legal Values 0 = None
0 = Default
4 = PXE
8 = HDD
20 = CD-DVD
24 = BIOS
28 = vFDD
32 = vCD-DVD
40 = SD
44 = RFS
48 = F11
52 = F10
60 = FDD
Default
0 = None
cfgServerBootOnce (Read/Write)
Table 209. Details of cfgServerBootOnce
Description Enables or disables the server boot once feature.
This object is read-write.
Legal Values 1 = TRUE
0 = FALSE
Default 0
cfgStorageModule
This group contains the parameters to configure storage sleds.
Use this command with the config and getconfig commands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
The following sections provide information about the objects in the cfgStorageModule group.
cfgStorageModuleStorageMode (Read/Write)
Table 210. Details of cfgStorageModuleStorageMode
Description
Displays the configuration mode of the storage sled.
Legal Values 2 — Split-single
1 — Split-dual
0 — Joined
CMC Property Database Group and Object Descriptions 129