CLI Guide
cfgLanNetworking
This group contains parameters to configure CMC NIC for IPv4.
One instance of the group is allowed. Some objects in this group may require CMC NIC to be reset, which may cause a brief loss in
connectivity. Objects that change CMC NIC IP address settings close all active user sessions and require users to reconnect using the
updated IP address settings.
For CMC, use this object with the config or getconfig subcommands.
To use this object property for CMC, you must have the Chassis Configuration Administrator privilege.
NOTE: For CMC, you can configure a setting that does not have a hash sign (#) prefixed in the output. To modify a
configurable object, use the –o option.
The following sections provide information about the objects in the cfgLanNetworking group.
cfgNicIPv4Enable - Read or Write
Table 118. Details of cfgNicIPv4Enable
Description Enables or disables the IPv4 stack.
Legal Values • 1 (TRUE)
• 0 (FALSE)
Default • For iDRAC: 0
• For CMC: 1
cfgNicVLanEnable - Read or Write
Table 119. Details of cfgNicVLanEnable
Description Enables or disables the VLAN capabilities.
All chassis management traffic, including the CMC and all iDRACs, resides on this external VLAN
when enabled. No iDRAC configuration change is required to use this external management network
VLAN.
Legal Values • 1 (TRUE)
• 0 (FALSE)
Default 0
Example • racadm config -g cfgLanNetworking -o cfgNicVLanEnable 1
• racadm config -g cfgLanNetworking -o cfgNicVLanEnable 0
cfgNicVLanId - Read or Write
Table 120. Details of cfgNicVLanId
Description Specifies the VLAN ID for the network VLAN configuration in CMC. This property is only valid if
cfgNicVLanEnable is set to 1(enabled).
Legal Values 1 – 4000 and 4021 – 4094
Default 1