Release Notes

After Shared PERC8 controller update, RAID related operations may take longer to report status.
Resolution
Wait for the operation status to report.
Versions/Systems Affected
CMC version 2.01 for Dell PowerEdge VRTX.
Issue 3:
Description
An error occurs while importing CMC configuration file using local racadm or remote racadm.
Resolution
This issue occurs when IPv6 is enabled or disabled from the configuration file. Enable or disable IPv6 using
the command “racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0”.
Versions/Systems Affected
CMC 2.0 or later for Dell PowerEdge VRTX
Issue 4:
Description
At times when foreign drives are inserted, the Chassis Overview Health tab does not display the alert,
“Foreign Configuration was detected on Physical Disk”.
Resolution
None. The alert is not displayed only at times. But, the functionality for foreign configuration is not affected.
Versions/Systems Affected
All CMC versions including CMC 2.23 for Dell PowerEdge VRTX.
Issue 5:
Description
When CMC firmware is downgraded to 1.36 from 2.00 or later while network share is configured, the Server
Components Update page gets corrupted.
Resolution
Clear the network configuration before downgrading to 1.36
Versions/Systems Affected
CMC Version 1.36 or earlier for Dell PowerEdge VRTX
Issue 6:
Description
When pinned cache is present, the controller failover feature does not work.
Resolution
Address the pinned cache before controller failover is allowed.
Versions/Systems Affected
All CMC versions including CMC 2.23 for Dell PowerEdge VRTX.