Users Guide
Configuring FlexAddress for chassis-level fabric and slots
At the chassis level, you can enable or disable the FlexAddress feature for fabrics and slots. FlexAddress is enabled on a per-fabric–basis
and then slots are selected for participation in the feature. Both fabrics and slots must be enabled to successfully configure FlexAddress.
Viewing World Wide Name or Media Access Control IDs
The WWN/MAC Summary page allows you to view the World Wide Name (WWN) configuration and Media Access Control (MAC)
address of a slot in the chassis.
Command messages
The following table lists the RACADM commands and output for common FlexAddress situations.
Table 26. FlexAddress commands and output
Situation Command Output
SD card in the CMC module is bound to
another service tag.
$racadm featurecard -s
The feature card inserted is
valid and contains the following
feature(s)
FlexAddress: bound to another
chassis, svctag = <Service tag
Number> SD card SN = <Valid flex
address serial number>
SD card in the CMC module that is
bound to the same service tag.
$racadm featurecard -s
The feature card inserted is
valid and contains the following
feature(s)
FlexAddress: bound
SD card in the CMC module that is not
bound to any service tag.
$racadm featurecard -s
The feature card inserted is
valid and contains the following
feature(s)
FlexAddress:not bound
FlexAddress feature not on the chassis
for any reason (No SD card inserted/
corrupt SD card/ after feature
deactivated /SD card bound to a
different chassis).
$racadm setflexaddr [-f
<fabricName> <slotState>]
$racadm setflexaddr [-i <slot#>
<slotstate>]
ERROR: Flexaddress feature is
not active on the chassis
Guest user attempts to set FlexAddress
on slots/fabrics.
$racadm setflexaddr [-f
<fabricName> <slotState>]
$racadm setflexaddr [-i <slot#>
<slotstate>]
ERROR: Insufficient user
privileges to perform operation
Deactivating FlexAddress feature with
chassis powered ON.
$racadm feature -d -c
flexaddress
ERROR: Unable to deactivate the
feature because the chassis is
powered ON
Guest user tries to deactivate the
feature on the chassis.
$racadm feature -d -c
flexaddress
ERROR: Insufficient user
privileges to perform operation
Changing the slot/fabric FlexAddress
settings while the server modules are
powered ON.
$racadm setflexaddr -i 1 1
ERROR: Unable to perform the set
operation because it affects a
powered ON server
Using FlexAddress and FlexAddress Plus cards 121