CLI Guide

setflexaddr
Table 92. Details of setflexaddr
Description Enables or disables FlexAddress on a particular slot or fabric.
To use this subcommand, you must have the Chassis Configuration Administrator privilege.
If the fabric type is determined to be Infiniband, the operation is canceled and the command returns an
error. If the FlexAddress feature is not activated, the command returns an error.
NOTE: The server must be turned off to change the slot state. All servers must be turned
off to change the fabric state. The MAC/WWN addresses must be managed locally (not
by an external console) to use this command.
Synopsis
racadm setflexaddr [-i <slot#> <state>][-f <fabricName> <state>]
< slot# > = 1 to 4
< fabricName > = A1 or A2
< state > = 0 or 1
where 0 is disable and 1 is enable.
Input -i <slot#> <state> — Enables or disables FlexAddress for the specified slot.
-f <fabricName> <state> — Enables or disables FlexAddress for the specified fabric.
Example
racadm setflexaddr -i 1 0
Slot 1 FlexAddress state set successfully
racadm setflexaddr -f A 1
Fabric A FlexAddress state set successfully
racadm setflexaddr -f idrac 1
setled
Table 93. Details of setled
Description Sets the state (blinking or not blinking) of the LED on the specified module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administrator
privilege on CMC. To enable the servers to blink or unblink, you must have the Server
Administrator or Debug Administrator privilege on CMC.
Synopsis
racadm setled -m <module> -l <ledState>
Input -m<module> — Specifies the module whose LED you want to configure.
<module> can be one of the following:
— server-n, where n=1–4
— switch-n, where n=1–2
— cmc-active
— chassis
RACADM Subcommand Details 83