CLI Guide
Table 61. Details of getslotname (continued)
• Display the name of the third slot.
racadm getslotname -i 3
• Verify if the option ‘0’ is set for displaying the slot name.
• Verify if the option ‘1’ is set for displaying the host name.
• Verify if the option ‘2’ is set for displaying the iDRAC DNS name.
getsensorinfo
Table 62. Details of getsensorinfo
Description
Displays status of chassis sensors.
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getsensorinfo
Table 63. Examples
<Sensor Name> <Status> <Reading> <LC> UC
CPU1 VCORE PG OK 0 600 N/A
System Board 12V PG OK 0 600 N/A
System Board 3.3V PG OK 4037 600 N/A
System Board 5V PG OK 4045 600 N/A
CPU1 PLL PG OK 4107 600 N/A
System Board 1.5V PG OK 0 600 N/A
System Board 1.1V PG OK 0 600 N/A
CPU1 M01 VTT PG OK 0 600 N/A
CPU1 M23 VDDQ PG OK 0 600 N/A
CPU1 M23 VTT PG OK 0 600 N/A
CPU1 VSA PG OK 0 600 N/A
CPU1 M01 VDDQ PG OK 0 600 N/A
NDC PG OK 0 600 N/A
CPU1 VTT PG OK 0 600 N/A
MEZZB PG OK 0 600 N/A
MEZZC PG OK 0 600 N/A
PERC1 PG OK 0 600 N/A
Table 64. Current sensor
<Sensor Name> <Status> <Reading> <LW> <LC> <UW> <UC>
System Board Current OK 22 3 -7 42 47
Sensor Type: Processor
<Sensor Name> <Status> <AC-OK status> <lc> <uc>
CPU1 Status OK Presence Detected N/
A N/A
RACADM Subcommand Details
57