CLI Guide
getmodinfo
Table 52. Details of getmodinfo
Description
Displays configuration and status information for all modules or a specified module (server, storage sled, switch,
CMC, fan unit, blower, power supply unit, chassis, main-board, IO cable, and FPC cable) in the chassis.
To use this subcommand, you must have CMC Login User privilege.
NOTE: The Service Tag field is blank for modules that do not have Service Tags.
Synopsis
racadm getmodinfo [-m <module>] [-A]ra
Input
• -m < module > — Specifies the module for which the configuration and status information is required. The
default command (no options) displays information about all the major components in the chassis.
<module > can be one of the following values:
○ server-n , where n = 1 to 4
○ server-nx , where n = 1 to 4; x = a to d
○ switch-n , where n = 1 or 2
○ pcie-n , where n = 1 to 8
○ CMC-n , where n = 1
○ fan-n , where n = 1 to 8
○ ps-n , where n = 1 to 2
○ chassis
○ main-board
○ io-cable
○ fpc cable
• -A — Does not display the headers and labels in the output.
Example
Table 53. Details
<module> <presence
>
<pwrStat
e>
<health> <svcTag> <node Id>
Chassis
Present ON OK ST0MP19 N/A
Main-
Board
Present ON OK N/A N/A
Storage-
2
Present OFF Not OK 6666666 N/A
Storage-
3
Present OFF Not OK 6666666 N/A
Storage-
4
Present OFF OK 6666666 N/A
Fan-1 Present ON OK N/A N/A
48 RACADM Subcommand Details