CLI Guide
getdcinfo
Table 29. Details of getdcinfo
Description Displays general I/O module and daughter card configuration information. Only the CMC controls
daughter cards.
To use this subcommand, you must have the CMC Login User privilege.
NOTE: Fabric verification for server DCs is performed only when the chassis is turned
on. When the chassis is on stand-by power, iDRACs on the server modules remain
turned off and thus are unable to report the server's DC fabric type. The DC fabric
type may not be reported in the CMC user interface until iDRAC on the server is
turned on.
Synopsis
racadm getdcinfo
Input -n — Displays the model names for the daughter cards in servers.
Table 30. Example
<IO#> <Type> <State> <Role>
switch-1 Gigabit Ethernet OK Master
Table 31. Server- state
<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>
server-1 Present PCIe OK PCIe OK
server-2 Not Present None N/A None N/A
server-3 Present PCIe OK None N/A
server-4 Not Present None N/A None N/A
Table 32. getdcinfo
<Server#> <Presence> <DC1 Model Name> <DC2 Model Name>
server-1 Present None None
server-2 Not Present None None
server-3 Not Present None None
server-4 Present None Broadcom M5708t
RACADM Subcommand Details 37