CLI Guide
Table 15. Details of eventfilters (continued)
• cmc.alert.all
• cmc.alert.audit
• cmc.alert.audit.lic
• cmc.alert.audit.warning
•
cmc.alert.audit.lic.critical
Input
• get — Displays the list of event filter settings.
• set — Configures the actions and notifications for a given event filter configuration.
• -c — Alert descriptor of the specific event filter.
• -n — The notification to be sent when the event occurs. Valid values are all, snmp, ipmi, email, or
none. You can append multiple notifications separated by a comma. You cannot enter the values
all or none with other notifications.
NOTE: If both event generation interval and notifications are configured and there is an
error while configuring the notifications, the event generation interval is not set. The
valid values are from 0–365. 0 disables the event generation.
Example
• Display all available event filter configurations:
racadm eventfilters get -c cmc.alert.all
• Display eventfilter configurations for a specific category. For example, audit:
racadm eventfilters get -c cmc.alert.audit
• Display eventfilter configurations for a specific subcategory. For example, licensing under the
audit category:
racadm eventfilters get -c cmc.alert.audit.lic
• Display eventfilter configurations for a specific severity. For example, warning under the audit
category:
racadm eventfilters get -c cmc.alert.audit.warning
• Display eventfilter configurations for a specific severity and subcategory. For example, a severity
of warning in the subcategory licensing under audit category:
racadm eventfilters get -c cmc.alert.audit.lic.warning
• Clear all available alert settings: racra
racadm eventfilters set -c cmc.alert.all -n none
• Configure using subcategory as a parameter. For example, all configurations under the licensing
subcategory in the audit category are assigned poweroff as action and all notifications are
enabled:
racadm eventfilters set -c cmc.alert.audit.lic -n all
• Configure using subcategory and severity as parameters. For example, all Information events
under the licensing subcategory in the audit category are assigned poweroff as action and all
notifications are disabled:
racadm eventfilters set -c cmc.alert.audit.lic.info -n none