CLI Guide
Table 279. Details of cfgChassisPowerCapFPercent (continued)
NOTE: If the specified percent is lower than the minimum value, the CMC will set the
value to the minimum value.
Default 100
cfgChassisRedundancyPolicy (Read/Write)
Table 280. Details of cfgChassisRedundancyPolicy
Description Sets the redundancy policy of the chassis.
Legal Values • 0 — No redundancy
• 1 — Grid redundancy
• 3 — Redundancy alerting only
• 4 — Fault tolerant redundancy
Default 3 — Redundancy alerting only
cfgChassisInMaxPowerCapacity (Read Only)
Table 281. Details of cfgChassisInMaxPowerCapacity
Description Indicates the total chassis power budget (in watts) available for chassis operation.
Legal Values None
Default None
cfgChassisInRedundancyReserve (Read Only)
Table 282. Details of cfgChassisInRedundancyReserve
Description Indicates the amount of redundant power (in Watts) in reserve that can be utilized in the event of an
AC grid or PSU failure. This value is 0 if the Redundancy Policy is set to 0 (no redundancy).
Legal Values 0 (disabled)
1 (enabled)
Default None
cfgChassisPowerClear (Write Only)
Table 283. Details of cfgChassisPowerClear
Description Resets cfgChassisMinPower and cfgChassisMaxPowerCapacity, when set to 1.
Legal Values None
Default None
CMC Property Database Group and Object Descriptions 143