CLI Guide

cfgRacTuneWebserverEnable (Read/Write)
Table 187. Details of cfgRacTuneWebserverEnable
Description Enables or disables the Web server. If this property is disabled, CMC is not accessible using client
Web browsers. This property has no effect on the Telnet/SSH or RACADM interfaces.
Legal Values 1 (TRUE)
0 (FALSE)
Default 1
cfgRacTuneFipsModeEnable
Table 188. Details of cfgRacTuneFipsModeEnable attribute
Description Enables or disables the FIPS mode.
Legal Values 0 and 1
Default 0
Usage
racadm getconfig -g cfgRacTuning -o
cfgRacTuneFipsModeEnableracadm config -g
cfgRacTuning -o cfgRacTuneFipsModeEnable 1
NOTE: The firmware racadm prompts you to confirm whether the FIPS mode has to be enabled, but remote racadm
does not prompt you to do so.
cfgRacTuneTLSProtocolVersionEnable
Table 189. Details of cfgRacTuneTLSProtocolVersionEnable attribute
Description
Sets the minimum TLS protocol version.
Legal Values
0 - TLSv1.0, TLSv1.1, and TLSv1.2 are enabled.
1 - TLSv1.1 and TLSv1.2 are enabled.
2 - only TLSv1.2 is enabled.
Default 1
cfgRacTuneChassisNameInPromptEnable
Table 190. Details of cfgRacTuneChassisNameInPromptEnable attribute
Description Enables or disables display of the chassis name in the SSH prompt.
Legal Values
0—Disable
1—Enable
Default 0
NOTE: You must have the chassis configuration administrator privilege to set and get the
cfgRacTuneChassisNameInPromptEnable attribute.
122 CMC Property Database Group and Object Descriptions