Release Notes
Resolution
Wait for the operation status to report.
Versions/Systems Affected
CMC version 2.01 for Dell PowerEdge VRTX.
Issue 4:
Description
An error occurs while importing CMC configuration file using local racadm or remote racadm.
Resolution
This issue occurs when IPv6 is enabled or disabled from the configuration file. Enable or disable IPv6 using the
command,
“racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0”.
Versions/Systems Affected
CMC 2.0 or later for Dell PowerEdge VRTX
Issue 5:
Description
At times when foreign drives are inserted, the Chassis Overview Health tab does not display the alert, “Foreign
Configuration was detected on Physical Disk”.
Resolution
None. The alert is not displayed only at times. But, the functionality for foreign configuration is not affected.
Versions/Systems Affected
All CMC versions including CMC 2.20 for Dell PowerEdge VRTX.
Issue 6:
Description
When CMC firmware is downgraded to 1.36 from 2.00 or later while network share is configured, the Server
Components Update page gets corrupted.
Resolution
Clear the network configuration before downgrading to 1.36
Versions/Systems Affected
CMC Version 1.36 or earlier for Dell PowerEdge VRTX
Limitations
Issue 1:
Description
In the Microsoft Edge browser, the Boot Identity Profiles page in the CMC GUI is slow when 1500 or more MAC
addresses are created from the MAC pool for the Boot Identity profile.