Reference Guide

Congure a CMC from an XML conguration le on a remote NFS share
racadm set -f myfile.xml -t xml -l 192.168.0.0:/myshare
setassettag
Description Sets the N-byte ASCII asset tag for the chassis.
To use this subcommand, you must have the Administrator privilege.
NOTE: The special characters \ (backslash), & (ampersand), ` (backward quotation
mark), and " (double quotation mark) are not supported for this subcommand.
Synopsis
racadm setassettag -m chassis <asset tag>
Input -m <module> — Species the module whose asset tag you want to set.
Legal value: chassis
You can obtain the same output if you do not include this option, because there is only one legal
value.
<assettag> is a maximum of 64 non-extended ASCII characters.
Example
racadm setassettag -m chassis 783839–33
racadm setassettag 783839–33
The asset tag was changed successfully.
setchassisname
Description
Sets the name of the chassis in the LCD.
To use this subcommand, you must have the Administrator
privilege.
NOTE: The special characters \ (backslash), &
(ampersand), ` (back quote), and " (double quote) are
not supported for this subcommand.
Synopsis
racadm setchassisname <name>
NOTE: Chassisname is a maximum of 64 non-extended
ASCII characters.
Example
racadm setchassisname dellchassis-1
The chassis name was set successfully.
set controllers
Description
Sets the RAID controllers detected in the system and fault-tolerant mode is congured on external
controllers (Shared PERC 8 External).
Synopsis To enable fault-tolerant mode:
Racadm raid set controllers:<FQDD of controller> -p HighAvailabilityMode
ha
90