Reference Guide

racadm raid createsecuritykey:RAID.ChassisIntegrated.1-1 -key <Key
id> -passwd <passphrase>
racadm raid modifysecuritykey:RAID.ChassisIntegrated.1-1 -key <Key
id> -oldpasswd <oldpassphrase> -newpasswd <newpassphrase>
racadm raid deletesecuritykey:RAID.ChassisIntegrated.1-1
racadm raid encryptvd:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid cryptographicerase:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
racadm raid unlock:RAID.ChassisIntegrated.1-1 -key <Key id> -passwd
<passphrase>
rebuild
Description
Starts a rebuild on a specied virtual drive.
Synopsis
racadm raid rebuild:<PQ FQDD> {-current | -pending}
Input
–current <optional>: Performs the conguration.
NOTE: If this requires the system to restart, the system is restarted.
–pending: Save the conguration change for a later use. You can use a combination of the –pending and –
current ags on multiple commands to reduce the possible number of system restarts.
Example
racadm raid rebuild:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
resetcong
Description
Removes the current RAID Conguration (Virtual Drives and Hotspares) from the RAID controller. This
operation is not data-distructive, but is dicult to reverse.
Synopsis
racadm raid resetconfig:<Controller FQDD> {-current|pending}
Input
–current <optional>: Performs the conguration right now.
NOTE: If this requires the system to reboot, then the system will reboot.
–pending: Save the conguration change for a later application. You can use a combination of the –
pending and –current ags on multiple commands to reduce the possible number of system reboots.
Example
racadm raid resetconfig:RAID.ChassisIntegrated.1-1
enableperc
Description
Indicates the RAID conguration of hardware RAID connected to the server. This subcommand enables the
power to a RAID card.
NOTE:
Using this subcommand will power cycle the chassis and set the fault-tolerant system conguration
to fault-tolerant mode.
If any PERC adapter settings are changed or rmware is updated, a message is displayed and the
fault-tolerant status is degraded. Make sure that the rmware and the settings of the SHARED PERC
match to set the fault-tolerant system conguration to fault-tolerant mode.
Synopsis
racadm raid enableperc:<AdapterFQDD>
Example
racadm raid enableperc:RAID.ChassisIntegrated.2-1
85