Reference Guide
Input
• –current <optional>: Performs the conguration right now.
NOTE: If this requires the system to reboot it will reboot then.
• –pending: Save the conguration change for a later application. You can use a combination of the –
pending and –current ags on multiple commands to reduce the possible number of system reboots.
• –speed{fast | full}: Perform a fast or full (slow) initialization on the virtual drive.
Example
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed fast
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed full
raid
Description Monitors, retrieves inventory, and congures the storage components connected to the chassis.
NOTE: To use this subcommand, you must have the Chassis Administrator privilege.
Synopsis
racadm raid get status
racadm raid get <Object type>
racadm raid get <Object type> -o
racadm raid get <Object type> -o -p <property names separated by comma>
racadm raid get <Object type>:<FQDD's of Object type separated by
comma>
racadm raid set <Set Operation>:<FQDD of Object type>
racadm raid set <Set Operation> -pdkey:<FQDD of PD>
racadm raid set <Set Operation> -vdkey:<FQDD of VD>
Input
NOTE:
• Maximum property names that can be specied in –p option is 10.
• Maximum FQDDs that can be specied is 3.
• (Object type) — controllers, vdisks, pdisks.
• Set Operation
– resetcong
– exportlog
– forceonline
– deletevd
– blink
– unblink
– clearcong
– importcong
– ccheck
– cancelcheck
– patrolread
– hotspare
– init
– assignva
– createvd
• –o — Displays all the properties of the selected Key or Object.
• –p — Displays the property names with lter.
• FQDD — Displays all the properties of the FQDD's Key.
83