Reference Guide

Input
–current <optional>: Performs the conguration right now.
NOTE: If this requires the system to reboot it will reboot then.
–pending: Save the conguration change for a later application. You can use a combination of the –
pending and –current ags on multiple commands to reduce the possible number of system reboots.
–speed{fast | full}: Perform a fast or full (slow) initialization on the virtual drive.
Example
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed fast
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -speed full
raid
Description Monitors, retrieves inventory, and congures the storage components connected to the chassis.
NOTE: To use this subcommand, you must have the Chassis Administrator privilege.
Synopsis
racadm raid get status
racadm raid get <Object type>
racadm raid get <Object type> -o
racadm raid get <Object type> -o -p <property names separated by comma>
racadm raid get <Object type>:<FQDD's of Object type separated by
comma>
racadm raid set <Set Operation>:<FQDD of Object type>
racadm raid set <Set Operation> -pdkey:<FQDD of PD>
racadm raid set <Set Operation> -vdkey:<FQDD of VD>
Input
NOTE:
Maximum property names that can be specied in –p option is 10.
Maximum FQDDs that can be specied is 3.
(Object type) — controllers, vdisks, pdisks.
Set Operation
resetcong
exportlog
forceonline
deletevd
blink
unblink
clearcong
importcong
ccheck
cancelcheck
patrolread
hotspare
init
assignva
createvd
–o — Displays all the properties of the selected Key or Object.
–p — Displays the property names with lter.
FQDD — Displays all the properties of the FQDD's Key.