Reference Guide

Example
racadm raid cancelrebuild:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
assignva
Description
Assigns a virtual disk to one or more virtual adapters.
NOTE: You can assign virtual disk to multiple virtual adapters when you select the mode of
assignment as multiple.
Synopsis
racadm raid assignva:<VA FQDD> -vdkey:<VD FQDD> -accesspolicy {na | rw} -
assignpolicy {single | multiple}{-current | -pending}
Input
–current <optional>: Performs the conguration right now.
NOTE: If this requires the system to reboot, the system will reboot then.
–pending: Save the conguration change for a later application. You can use a combination of the –
pending and –current ags on multiple commands to reduce the possible number of system restarts.
–assignpolicy {single|multiple}: Uses the specied assign policy to determine if the Virtual Disk can be
assigned to multiple Virtual Adapters.
NOTE: Enable cluster services on the servers when assigning Virtual Disk to multiple Virtual
Adapters. Use of this mode without Cluster Services may lead to corrupted or lost data.
–accesspolicy {na | rw}: Set the access policy to No Access or Read/Write.
–vdkey:<VD FQDD>: The Virtual Drive to change the access to.
Example
racadm raid assignva:RAID.ChassisIntegrated.1-1-1 -vdkey:Disk.Virtual.
0:RAID.ChassisIntegrated.1-1 -accesspolicy { na | rw }
racadm raid assignva:RAID.ChassisIntegrated.1-1-2 -vdkey:Disk.Virtual.
0:RAID.ChassisIntegrated.1-1 -accesspolicy rw -assignpolicy multiple
unblink
Description
Stops blinking or identies an operation on the specied device.
Synopsis
racadm raid unblink:<PD FQDD>
racadm raid unblink:<VD FQDD>
racadm raid unblink {-pdkey:<comma separated PD FQDDs|-vdkey:<comma
separated VD FQDDs}
racadm raid unblink:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Input
–pdkey: A comma-seperated list of physical disk drive FQDDs to use in the operation.
–vdkey: A comma-seperated list of virtual drive FQDDs to use in the operation.
Example
racadm raid unblink:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
racadm raid unblink:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid unblink -pdkey:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1,Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
racadm raid unblink -vdkey:Disk.Virtual.0:RAID.ChassisIntegrated.
1-1,Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid unblink:Enclosure.External.0-0:RAID.ChassisSlot.5-1
init
Description
Starts an initialization operation on the specied virtual drive.
Synopsis
racadm raid init:<VD FQDD> -speed {fast | full} {-current | -pending}
82