Reference Guide
Speed = 4670 RPMS
Fan.Slot.3:Enclosure.External.0-0:RAID.ChassisSlot.5-1
FanOperationalStatus = Ok
State = Ready
Name = Fan 3
Speed = 4700 RPMS
get psus
Description Displays the status and attributes of the Power Supply Unit (PSU) in the storage enclosure that are
connected to chassis
NOTE: To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm raid get psus -o -p Status
racadm raid get psus -o
Input
• -o — The -o is used to display the fault-tolerant status of a enclosure.
Example
racadm raid get psus -o -p Status
PSU.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
PSU.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
PSU.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
PSU.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
racadm raid get psus -o
PSU.Slot.0:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = PSU 0
PartNumber = 0NFCG1A01
PSU.Slot.1:Enclosure.External.0-1:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = PSU 1
PartNumber = 0NFCG1A01
PSU.Slot.0:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = PSU 0
PartNumber = 0D1YWRA00
PSU.Slot.1:Enclosure.External.0-0:RAID.ChassisSlot.5-1
Status = Ok
State = Ready
Name = PSU 1
PartNumber = 0GV5NHA00
get tempprobes
Description
Displays the status and attributes of the temperature sensors in the storage enclosure that are connected
to chassis
NOTE: To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm raid get tempprobes -o -p Status
racadm raid get tempprobes -o
79