Reference Guide

–pending: Save the conguration change for a later application. You can use a combination of the –
pending and –current ags on multiple commands to reduce the possible number of system reboots.
Example
racadm raid deletevd:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
discardcache
Description
Discards any pinned or persistent cache present on the RAID controller.
Synopsis
racadm raid discardcache:<Controller FQDD> {-current | -pending}
Input
–current <optional>: Performs the conguration right now.
NOTE: If this requires the system to reboot, the system is rebooted.
–pending: Save the conguration change for a later application. You can use a combination of the –
pending and –current ags on multiple commands to reduce the possible number of system reboots.
Example
racadm raid discardcache:RAID.ChassisIntegrated.1-1
exportlog
Description
Export a log from the device.
Synopsis
racadm raid exportlog:<FQDD> -l<CIFS or NFS share> -u<username> -p
<password> [-f <filename>]
Input
–l<CIFS or NFS share>: The network share to write the log to.
–u<username: The network username for the share.
–p <password>: The network password for the share
–f <lename>: The le name to write the log to.
Example
racadm raid exportlog:RAID.ChassisIntegrated.1-1 -l <CIFS or NFS share> -
u<username> -p <password> [-f <filename>]
forceonline
Description
Forces the RAID Controller to make the specied drive online. This operation may result in obsolete or
corrupted data, and should only be attempted in cases where a rebuild operation has failed or is not applicable.
Synopsis
racadm raid forceonline:<PD FQDD> {current|pending}
Input
–current <optional>: Performs the conguration right now.
NOTE: If this requires the system to reboot, then the system is rebooted.
–pending: Save the conguration change for a later application. You can use a combination of the –
pending and –current ags on multiple commands to reduce the possible number of system reboots.
Example
racadm raid forceonline:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
get controllers
Description
The command lists all RAID controllers detected in the system and their properties.
73