Reference Guide

Current DNS Server 1 = 192.168.0.1
Current DNS Server 2 = 0.0.0.0
DNS Servers from DHCP = 1
CMC IPv6 Information:
IPv6 Enabled = 0
Autoconfiguration Enabled = 1
Link Local Address = ::
Current IPv6 Address 1 = ::
Current IPv6 Gateway = ::
Current IPv6 DNS Server 1 = ::
Current IPv6 DNS Server 2 = ::
DNS Servers from DHCPv6 = 1
Chassis Information:
System Model = PowerEdge VRTX
System AssetTag = 00000
Service Tag =
Express Service Code =
Chassis Name = CMC-
Chassis Location = [UNDEFINED]
Chassis Midplane Version = 1.0
Power Status = ON
System ID = 1487
Examples
racadm getsysinfo -d
racadm getsysinfo -c
racadm getsysinfo -A
racadm getsysinfo -4
racadm getsysinfo -6
gettracelog
Description
Lists all the trace log entries in CMC.
Synopsis
racadm gettracelog -i [-A]
racadm gettracelog [-s <start>] [-c <count>] [--more] [-A] [-o]
Input
-i - Displays the number of entries in iDRAC trace log.
--more - Displays one screen at a time and prompts the user to continue (similar to the UNIX more
command).
-o - Displays each entry in a single line.
-c - Species the number of records to display.
-s - Species the starting record to display.
-A - Does not display headers or labels.
NOTE: The -A and -o options are deprecated.
Output The default output display shows the record number, timestamp, source, and description. The timestamp
begins at midnight, January 1 and increases until the system boots. After the system boots, the system’s
timestamp is used.
57