Reference Guide

Fan-5 OK 4107 840 600 N/A N/A
Fan-6 OK 0 840 600 N/A N/A
Blower-1 N/A 0 3000 2250 N/A N/A
Blower-2 N/A 0 3000 2250 N/A N/A
Blower-3 N/A 0 3000 2250 N/A N/A
Blower-4 N/A 2611 3000 2250 N/A N/A
Sensor Type : Temperature
Sensor Units : Celsius
<Sensor Name> <Status
>
<Reading
>
<LW> <LC> <UW> <UC>
Chassis
Ambient
OK 22 3 -7 42 47
Server-4 OK 20 3 -7 42 47
Sensor Type : Power
<
Sensor Name> <Status> <AC-OK status>
PS-1 Slot Empty N/A
PS-2 Online OK
PS-3 Slot Empty N/A
PS-4 Slot Empty N/A
Sensor Type : Cable
<
Sensor Name> <Status>
IO-Cable OK
FPC-Cable OK
Sensor Type : Intrusion
<Sensor Name> <Intrusion>
Chassis Intrusion Closed
getslotname
Description
Displays the name, host name (if available) and iDRAC DNS name of all the four slots, or of a
specied slot (indicated by the slot number) in the chassis. Optionally, use this command to nd if
the slot name or host name, or iDRAC DNS name is displayed in the CMC Web interface, or with the
getslotname [-i <slotNum> | -h] command. If the host name is not available, the static slot name is
used.
NOTE: Lengthy slot names, host names, or iDRAC DNS names are truncated when the slot
names are displayed.
To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getslotname
racadm getslotname [-i <slotNum> | -h]
racadm getslotname -h
Input
None -
Displays the slot name for all the four slots in the chassis.
-i <slotNum> - species the slot number.
Values: 1 to 4
54