Reference Guide
• Displays a list of the available conguration groups on iDRAC
in an alphabetical order.
racadm getconfig -h
• Displays the conguration properties for the user named
root.
racadm getconfig -u root
• Displays the user group instance at index 2 with verbose
information for the property values.
racadm getconfig -g cfgUserAdmin -i 2 -v
If you do not congure the following key attributes in their
respective groups for a particular index, the groups are not
saved in to the le. This is applicable for all the index groups.
Groups Key Attributes
cfgEmailAlert cfgEmailAlertAddress
cfgLDAPRoleGroup cfgLDAPRoleGroupDN
cfgServerInfo cfgServerBmcMacAddress
cfgStandardSchema cfgSSADRoleGroupName
cfgTraps cfgTrapsAlertDestIPAddr
cfgUserAdmin cfgUserAdminUserName
getdcinfo
Description
Displays general I/O module and daughter card conguration information. Only the CMC
controls daughtercards.
To use this subcommand, you must have the CMC Login User privilege.
NOTE: Fabric verication for server DCs is performed only when the chassis is turned
on. When the chassis is on stand-by power, iDRACs on the server modules remain
turned o and thus are unable to report the server's DC fabric type. The DC fabric
type may not be reported in the CMC user interface until iDRAC on the server is
turned on.
Synopsis
racadm getdcinfo
Input -n — Displays the model names for the daughter cards in servers.
Example
The following example is for a system with multi-slot servers.
racadm getdcinfo
Group A I/O Type : Gigabit Ethernet
Group B I/O Type : PCIe
Group C I/O Type : PCIe
<IO#> <Type> <State> <Role>
switch-1 Gigabit Ethernet OK Master
37