Reference Guide
• Display eventlter congurations for a specic severity and subcategory. For example, a
severity of warning in the subcategory licensing under audit category:
racadm eventfilters get -c cmc.alert.audit.lic.warning
• Clear all available alert settings:
racadm eventfilters set -c cmc.alert.all -n none
• Congure using severity as a parameter. For example, all informational events in storage
category are assigned powero as action, and email and snmp as notications:
racadm eventfilters set -c cmc.alert.storage.info -n email,snmp
• Congure using subcategory as a parameter. For example, all congurations under the licensing
subcategory in the audit category are assigned powero as action and all notications are
enabled:
racadm eventfilters set -c cmc.alert.audit.lic -n all
• Congure using subcategory and severity as parameters. For example, all Information events
under the licensing subcategory in the audit category are assigned powero as action and all
notications are disabled:
racadm eventfilters set -c cmc.alert.audit.lic.info -n none
fanoset
Description
Congures the internal fans to run at a higher speed than the normal speed.
To use this subcommand, you must have the Chassis Conguration Administrator privilege.
Synopsis
racadm fanoffset [-s <off|low|medium|high>
Valid category values are:
• o
• low
• medium
• high
Input s — Sets the fan speed.
Example
• Disable the fanoset feature.
racadm fanoffset -s off
• Increases fan speed by 20% of fan’s maximum speed. Minimum speed for fan is 35% of the
maximum.
racadm fanoffset -s low
• Increases fan speed by 50% of fan’s maximum speed. Minimum speed for fan is 65% of the
maximum.
racadm fanoffset -s medium
• Sets fans to run at 100% of fan’s maximum speed.
racadm fanoffset -s high
feature
Description
Displays all active chassis features. The information displayed includes feature name, date activated, and the
serial number of the SD card used to activate the feature.
Dell Feature Cards may contain more than one feature.
NOTE: To use this subcommand to deactivate FlexAddress or ExtendedStorage, you must have the
Chassis Conguration Administrator privilege. A user with login privileges can view status only.
30