Reference Guide

cfgRacTuneTelnetPort (Read/Write)
Description Species the port number used for iDRAC or CMC Telnet
interface.
NOTE: For CMC, the following port numbers are
reserved and cannot be used: 21, 68, 69, 111, 123, 161,
546, 801, 4096, 5988, 5989, 6900, 9000, and 60106.
Legal Values
For iDRAC: 1 – 65535
For CMC: 10 – 65535
Default 23
cfgRacTuneDaylightOset (Read Only)
Description Species the daylight savings oset (in minutes) to use for the RAC Time. This value is 0 if the time
zone is not a Daylight Saving time zone.
Legal Values 0 – 60
Default 0
cfgRacTuneTimezoneOset (Read Only)
Description
Species the time zone oset (in minutes) from Greenwich Mean Time (GMT)/Coordinated Universal Time
(UTC) to use for the RAC Time. Some common time zone osets for time zones in the United States are:
–480 (PST—Pacic Standard Time)
–420 (MST—Mountain Standard Time)
–360 (CST—Central Standard Time)
–300 (EST—Eastern Standard Time)
For CMC: This object property is read only. Species the dierence in number of seconds, from the UTC/GMT.
This value is negative if the current time zone is west of Greenwich.
Legal Values 720 to 7800
Default 0
cfgRacTuneWebserverEnable (Read/Write)
Description
Enables or disables the Web server. If this property is disabled,
CMC is not accessible using client Web browsers. This property
has no eect on the Telnet/SSH or RACADM interfaces.
Legal Values
1 (TRUE)
0 (FALSE)
Default 1