Reference Guide

This group enables/disables and congures rmware updates, NTP, remote syslogging, and SMTP email alerting.
Use this object with the config or getconfig subcommands.
To use this object property, you must have Chassis Conguration Administrator privilege.
The following sections provide information about the objects in the cfgRemoteHosts group.
cfgRhostsFwUpdateTftpEnable (Read/Write)
Description Enables or disables CMC rmware update from a network TFTP
server.
Legal Values
1 (TRUE)
0 (FALSE)
Default 1
cfgRhostsFwUpdateIpAddr (Read/Write)
Description Species the network TFTP server IPv4 or IPv6 address that is
used for TFTP CMC rmware update operations.
Legal Values A string representing a valid IPv4 or IPv6 address. For example,
192.168.0.61
Default For IPv4, it is 0.0.0.0
cfgRhostsFwUpdatePath (Read/Write)
Description
Species TFTP path where CMC rmware image le exists on
the TFTP server. The TFTP path is relative to the TFTP root
path on the TFTP server.
NOTE: The server may still require you to specify the
drive (for example, C:).
Legal Values A string with a maximum length of 255 ASCII characters.
Default <blank>
cfgRhostsSmtpServerIpAddr (Read/Write)
Description
The IPv4 or IPv6 address of the network SMTP server. The
SMTP server transmits e-mail alerts from CMC if the alerts are
congured and enabled.
Legal Values A string representing a valid SMTP server IPv4 or IPv6 address.
For example: 192.168.0.55.
Default
localhost.localdomain
111