Reference Guide

Table Of Contents
enableperc
Description
Indicates the RAID configuration of hardware RAID connected to the server. This subcommand enables the
power to a RAID card.
NOTE:
Using this subcommand will power cycle the chassis and set the fault-tolerant system configuration
to fault-tolerant mode.
If any PERC adapter settings are changed or firmware is updated, a message is displayed and the
fault-tolerant status is degraded. Make sure that the firmware and the settings of the SHARED
PERC match to set the fault-tolerant system configuration to fault-tolerant mode.
Synopsis
racadm raid enableperc:<AdapterFQDD>
Example
racadm raid enableperc:RAID.ChassisIntegrated.2-1
disableperc
Description
Indicates the RAID configuration of hardware RAID connected to the system. This subcommand disables
the power to a RAID card.
NOTE:
Using this subcommand power cycles the chassis and sets the fault-tolerant system configuration
to Single PERC mode.
Synopsis
racadm raid disableperc:<ControllerFQDD>
Example
racadm raid disableperc:RAID.ChassisIntegrated.2-1
createsecuritykey
Description
Assigns a security key to the controller.
Synopsis
racadm raid createsecuritykey:<ControllerFQDD> -key <Key id> -passwd
<passphrase>
Input
-key <Key id> key id. The key identifier can be a minimum of one character and maximum of 32
characters. It must not have spaces.
-passwd <passphrase> passphrase. The passphrase can be a minimum of eight characters and a
maximum of 32 characters. The passphrase must have one character from each of the following:
uppercase
lowercase
number
non-alphanumeric character except space
Example
racadm raid createsecuritykey:RAID.ChassisIntegrated.1-1 -key Key@123_ -
passwd Pass@123_
RACADM Subcommand Details 93