Reference Guide

Table Of Contents
racadm raid rename:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -name
<VD name>
racadm raid ctrlprop:RAID.ChassisIntegrated.1-1 [-rebuild <value>>]
[-bgi <value>] [-reconstruct <value>] [-checkconsistency <value>]
[-ccmode {abortonerror | normal}] [-copybackmode {off | on |
onwithsmart}] [-lb {auto | disabled}] [-prunconfigured {yes | no}]
racadm raid
rebuild:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
racadm raid
cancelrebuild:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrat
ed.1-1
racadm raid disableperc:RAID.ChassisIntegrated.2-1
racadm raid enableperc:RAID.ChassisIntegrated.2-1
racadm raid createsecuritykey:RAID.ChassisIntegrated.1-1 -key <Key
id> -passwd <passphrase>
racadm raid modifysecuritykey:RAID.ChassisIntegrated.1-1 -key <Key
id> -oldpasswd <oldpassphrase> -newpasswd <newpassphrase>
racadm raid deletesecuritykey:RAID.ChassisIntegrated.1-1
racadm raid encryptvd:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid
cryptographicerase:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisInt
egrated.1-1
racadm raid unlock:RAID.ChassisIntegrated.1-1 -key <Key id> -passwd
<passphrase>
rebuild
Description
Starts a rebuild on a specified virtual drive.
Synopsis
racadm raid rebuild:<PQ FQDD> {-current | -pending}
Input
current <optional>: Performs the configuration.
NOTE: If this requires the system to restart, the system is restarted.
pending: Save the configuration change for a later use. You can use a combination of the pending
and current flags on multiple commands to reduce the possible number of system restarts.
Example
racadm raid
rebuild:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
resetconfig
Description
Removes the current RAID Configuration (Virtual Drives and Hotspares) from the RAID controller. This
operation is not data-distructive, but is difficult to reverse.
Synopsis
racadm raid resetconfig:<Controller FQDD> {-current|pending}
Input
current <optional>: Performs the configuration right now.
NOTE: If this requires the system to reboot, then the system will reboot.
pending: Save the configuration change for a later application. You can use a combination of the
pending and current flags on multiple commands to reduce the possible number of system reboots.
Example
racadm raid resetconfig:RAID.ChassisIntegrated.1-1
92 RACADM Subcommand Details