Reference Guide

Table Of Contents
Table 19. createvd (continued)
-cc: Create a CacheCade or Enhanced Cache VD.
-vdinit: Create a virtual disk with or without initialization. The available values are:
yes
no
If -vdinit is not specified, the default value is yes.
-secure: Create a virtual disk using Self-Encrypting Drives (SEDs). The available values are:
yes
no
If -secure is not specified, the default value is no.
Example
racadm raid createvd:RAID.ChassisIntegrated.1-1 -rl r0 -
pdkey:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
NOTE: Make sure to provide the current active controller FQDD in the createvd command.
deletevd
Description
Deletes the specified virtual drive.
Synopsis
racadm raid deletevd:<VD FQDD> {-current|-pending}
Input
current <optional>: Performs the configuration right now.
NOTE: If this requires the system to reboot, it will reboot.
pending: Save the configuration change for a later application. You can use a combination of the
pending and current flags on multiple commands to reduce the possible number of system reboots.
Example
racadm raid deletevd:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
discardcache
Description
Discards any pinned or persistent cache present on the RAID controller.
Synopsis
racadm raid discardcache:<Controller FQDD> {-current | -pending}
Input
current <optional>: Performs the configuration right now.
NOTE: If this requires the system to reboot, the system is rebooted.
pending: Save the configuration change for a later application. You can use a combination of the
pending and current flags on multiple commands to reduce the possible number of system reboots.
Example
racadm raid discardcache:RAID.ChassisIntegrated.1-1
exportlog
Description
Export a log from the device.
RACADM Subcommand Details 79