Reference Guide

Table Of Contents
racdump
Description This subcommand displays the comprehensive chassis status
and configuration state information, and historic event logs.
Used for post-deployment configuration verification and
during debugging sessions.
To use this subcommand for CMC, you must have the
Administrator privilege.
Synopsis
racadm racdump
Input Racdump includes the following subsystems and aggregates
the following RACADM commands:
General System/RAC information - getsysinfo
Session information - getssinfo
Sensor information - getsensorinfo
Switches information (IO Module) - getioinfo
Mezzanine card information (Daughter card) -
getdcinfo
All modules information - getmodinfo
Power budget information - getpbinfo
KVM information - getkvminfo
NIC information (CMC module) - getniccfg
Redundancy information - getredundancymode
Trace log information - gettracelog
RAC event log - getraclog
System event log - getsel
Output
The following information is displayed when the
racdumpsubcommand is processed:
General system/RAC information
Coredump
Session information
Process information
Firmware build information
Example
racadm racdump
===============================================================================
General System/RAC Information
===============================================================================
CMC Information:
CMC Date/Time = Wed, 28 Nov 2007 11:55:49 PM
CMC Version = X08
Last Firmware Update = Wed Nov 21 21:37:56 2007
Hardware Version = 2
Current IP Address = 192.168.155.10
Current IP Gateway = 192.168.155.1
Current IP Netmask = 255.255.255.128
DHCP Enabled = 1
MAC Address = 00:55:AB:39:10:0F
Current DNS Server 1 = 0.0.0.0
Current DNS Server 2 = 0.0.0.0
DNS Servers from DHCP = 0
Register DNS CMC Name = 0
DNS CMC Name = cmc-servicetag
72
RACADM Subcommand Details