Reference Guide

Table Of Contents
10 GbE KR/3 Present F8:DB:88:3D:
A2:7B
Unknown FlexAddress
NOTE: 10 GbE KR/3 The value 3 indicates the protocol type.
Displays the console assigned MAC/WWN of all LOMs or mezzanine cards.
racadm getmacaddress -c all
<Name> <Type> <Presence> <Active WWN/MAC> <Partition
Status>
<Assignmen
t Type>
Server-1
-A
IDRAC-
Controller
Present 18:A9:9B:FD:C4:DF N/A Factory
Gigabit
Ethernet
Present 00:0A:00:0A:00:00 Unknown IO-
Identity
Server-3
-A
Gigabit
Ethernet
Present
84:8F:69:FC:E8:F1
Unknown Factory
Server-4
-A
10 GbE
KR/3
Present
F8:DB:88:3D:A2:7A
Unknown FlexAddres
s
FCoE-WWN Present 20:01:F8:DB:88:3D
:A2:7A
Unknown FlexAddres
s
getmodinfo
Table 16. getmodinfo
Description
Displays configuration and status information for all modules or a specified module (server, switch, CMC,
fan unit, blower, power supply unit, chassis, DVD, main-board, IO cable, and FPC cable) in the chassis.
To use this subcommand, you must have CMC Login User privilege.
NOTE: The service tag field is blank for modules that do not have service tags.
Synopsis
racadm getmodinfo [-m <module>] [-A]
Input
-m <module> Specifies the module for which the configuration and status information is required.
The default command (no options) displays information about all the major components in the chassis.
<module> can be one of the following values:
server-n, where n = 1 to 4
switch-n, where n = 1
CMC-n, where n = 1 or 2
fan-n, where n = 1 to 6
blower-n, where n = 1 to 4
ps-n, where n = 1 to 4
chassis
RACADM Subcommand Details 49