Reference Guide

Table Of Contents
0 Unsupported
1 ISCSI
2 FCoE-FIP
3 iSCSI/FCoE-FIP
To use this subcommand, you must have CMC Login User
privilege.
NOTE: If FlexAddress is not activated on the chassis, the
command displays server-assigned MAC/WWN addresses.
If the slot is empty, the command leaves the server-
assigned MAC/WWN addresses blank. If an external
console controls the MAC/WWN addresses, the command
displays an externally managed message.
Synopsis
racadm getflexaddr [-i <slotNum>]
Input -i <slotNum> Specifies the slot information to be displayed.
<slotNum> must be from 1 to 4.
Example
Displays the current FlexAddress settings for all the slots and fabrics.
racadm getflexaddr
<
Slot#>
<Status> <Server Presence>
1 Enabled Present
2 Enabled Present
3 Enabled Not Present
4 Enabled Not Present
<Fabric> <Type> <Status>
A Gigabit Ethernet Enabled
B None Enabled
C None Enabled
Displays the current FlexAddress setting for slot 4
racadm getflexaddr -i 4
Slot-4 server presence = Present
Slot-4 flexaddress enabled = 1
RACADM Subcommand Details
41