Reference Guide

Table Of Contents
Critical
Warning
Informational
Valid examples of alert descriptors are:
cmc.alert.all
cmc.alert.audit
cmc.alert.audit.lic
cmc.alert.audit.warning
cmc.alert.audit.lic.critical
Input
get - Displays the list of event filter settings.
set - Configures the actions and notifications for a given event filter configuration.
-c - Alert descriptor of the specific event filter.
-n - The notification to be sent when the event occurs. Valid values are all, snmp, ipmi, lcd,
email, or none. You can append multiple notifications separated by a comma. You cannot
enter the values all or none with other notifications.
NOTE: If both event generation interval and notifications are configured and there is
an error while configuring the notifications, the event generation interval is not set. The
valid values are from 0365. 0 disables the event generation.
Example
Display all available event filter configurations:
racadm eventfilters get -c cmc.alert.all
Display eventfilter configurations for a specific category. For example, audit:
racadm eventfilters get -c cmc.alert.audit
Display eventfilter configurations for a specific subcategory. For example, licensing under
the audit category:
racadm eventfilters get -c cmc.alert.audit.lic
Display eventfilter configurations for a specific severity. For example, warning under the
audit category:
racadm eventfilters get -c cmc.alert.audit.warning
Display eventfilter configurations for a specific severity and subcategory. For example, a
severity of warning in the subcategory licensing under audit category:
racadm eventfilters get -c cmc.alert.audit.lic.warning
Clear all available alert settings:
racadm eventfilters set -c cmc.alert.all -n none
Configure using severity as a parameter. For example, all informational events in storage
category are assigned poweroff as action, and email and snmp as notifications:
racadm eventfilters set -c cmc.alert.storage.info -n email,snmp
Configure using subcategory as a parameter. For example, all configurations under the
licensing subcategory in the audit category are assigned poweroff as action and all
notifications are enabled:
racadm eventfilters set -c cmc.alert.audit.lic -n all