Reference Guide

Table Of Contents
cfgChassisServerBasedPowerMgmtMode
Description Indicates the server-based power management mode of a chassis.
Legal Values
0 (disabled)
1 (enabled)
Default 0 (disabled)
cfgChassisPowerCapBTU (Read/Write)
Description Indicates the maximum power consumption limit (in BTU/hr)
for the entire chassis. The command generates an error if
server throttling is necessary to achieve the power goal based
on the value for this setting.
Legal Values 9264 - 56931 BTU/hr
Default 43221 BTU/hr
cfgChassisACPowerRecoveryDisable
Description
If AC power recovery is disabled, the chassis is powered off after power outage is restored.
Legal Values
0 Enable
1 Disable
Default
0
cfgKVMInfo
This group is used to view the mapping information for the KVM.
Use this object with the config or getconfig subcommands.
To use this object property, you must have Chassis Configuration Administrator privilege.
cfgKvmMapping Read or Write
Description
Maps the slots to the KVM.
Legal Values 1, 2, 3, and 4 are the slot numbers that are specified.
Default 1
cfgKvmSlot<num>Enable Read or Write
Description
Enable the slots (1 to 4) to access using KVM:
cfgKvmSlot1Enable
cfgKvmSlot2Enable
cfgKvmSlot3Enable
cfgKvmSlot4Enable
162 CMC Property Database Group and Object Descriptions