Reference Guide

Table Of Contents
cfgTrapsAlertDestIpAddr
Description Sets the IP address that receives the alert.
Legal Values A string representing a valid IP address. For example,
192.168.0.20.
Default None
cfgTrapsCommunityName
Description Sets the community string (identical to the community name)
used for authentication. The community string acts as a
password shared between different hosts over the network.
This community string value must match with that of the
other hosts for any kind of communication through SNMP.
Legal Values A string representing the community name.
Default None
cfgTrapsSNMPv3UserId (Read Only)
Table 20. cfgTrapsSNMPv3UserId Details
Description
Displays the SNMP user ID of an existing CMC user.
Legal Values
1-16
Default
Empty
cfgTrapsSNMPv3UserName
Table 21. cfgTrapsSNMPv3UserName Details
Description
Configure SNMPv3 user name.
Legal Values
Any existing CMC user name.
Default
Empty
cfgRacTuning
This group is used to configure various iDRAC or CMC configuration properties, such as valid ports and security port
restrictions.
Use this object with the config or getconfig subcommands.
To use this object property for CMC, you must have Chassis Configuration Administrator privilege.
NOTE:
For CMC, you can configure any setting that is not preceded by the hash sign (#) in the output. To modify a
configurable object, use the -o option.
Use the -m option to apply this setting to iDRAC.
The following sections provide information about the objects in the cfgRacTuning group.
134
CMC Property Database Group and Object Descriptions