Default 1
cfgRhostsFwUpdateIpAddr (Read/Write)
Description Specifies the network TFTP server IPv4 or IPv6 address that
is used for TFTP CMC firmware update operations.
Legal Values A string representing a valid IPv4 or IPv6 address. For
example, 192.168.0.61
Default For IPv4, it is 0.0.0.0
cfgRhostsFwUpdatePath (Read/Write)
Description
Specifies TFTP path where CMC firmware image file exists on
the TFTP server. The TFTP path is relative to the TFTP root
path on the TFTP server.
NOTE: The server may still require you to specify the
drive (for example, C:).
Legal Values A string with a maximum length of 255 ASCII characters.
Default <blank>
cfgRhostsSmtpServerIpAddr (Read/Write)
Description
The IPv4 or IPv6 address of the network SMTP server. The
SMTP server transmits e-mail alerts from CMC if the alerts
are configured and enabled.
Legal Values A string representing a valid SMTP server IPv4 or IPv6
address. For example: 192.168.0.55.
Default
localhost.localdomain
cfgRhostsNtpEnable
Description
Enables or disables the use of the Network Time Protocol (NTP) for date and time
synchronization.
Legal Values
1 (true)
0 (false)
Default 0
cfgRhostsNtpServer1
Description
Specifies the first of three possible NTP servers.
122 CMC Property Database Group and Object Descriptions