Reference Guide

Table Of Contents
racadm setflexaddr -f idrac 1
setled
Description Sets the state (blinking or not blinking) of the LED on the specified module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administrator
privilege on CMC. To enable the servers to blink or unblink, you must have the Server Administrator
or Debug Administrator privilege on CMC.
Synopsis
racadm setled -m <module> -l <ledState>
Input
-m <module> - Specifies the module whose LED you want to configure.
<module> can be one of the following:
server-n, where n=14
switch-n, where n=1
cmc-active
chassis
-l <ledstate> - Specifies whether the LED should blink.
<ledstate> can be one of the following:
0 no blinking
1 blinking
Example
racadm setled -m server-1 -1 1
LED state was set successfully.
NOTE: The setled command generates an error when used on the extension slot of a multi-slot
server.
racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
set enclosure
Description
Sets the asset tag and asset name of the enclosures.
NOTE: Set enclosure is used for the storage expansion feature when available with shared
external PERCs.
NOTE: You cannot modify the asset names for internal enclosures.
Synopsis
racadm raid set enclosures:
Enclosure.External.0-0:RAID.ChassisSlot.5-1 p AssetTag <value>
racadm raid set enclosures:
Enclosure.External.0-0:RAID.ChassisSlot.5-1 p AssetName <value>
Input
-p Specifies the property of the enclosure to be modified.
100 RACADM Subcommand Details