Users Guide

Table Of Contents
Diagnostics
The LCD panel helps you to diagnose issues in any server or module in the chassis. If there is an issue or fault with the chassis
or any server or other module in the chassis, the LCD panel status indicator blinks amber. On the Main Menu, an icon with an
amber background displays next to the menu item Enclosurethat leads to the Front, Rear, Side, or Enclosure status.
By following the amber icons through the LCD menu system, you can display the status screen and error messages for the item
that has the issue.
Error messages on the LCD panel can be removed by removing the module or server that is the cause of the issue, or by
clearing the hardware log for the module or server. For server errors, use the iDRAC web interface or command line interface to
clear the servers System Event Log (SEL). For chassis errors, use the CMC web interface or command line interface to clear
the hardware log.
Front Panel LCD Messages
This section contains two subsections that list error and status information that is displayed on the front panel LCD.
Error messages on the LCD have a format that is similar to the System Event Log (SEL) viewed from the CLI or Web interface.
The tables in the error section list the error and warning messages that are displayed on the various LCD screens and the
possible cause of the message. Text enclosed in angled brackets (< >) indicates that the text may vary.
Status information on the LCD includes descriptive information about the modules in the chassis. The tables in this section
describe the information that is displayed for each component.
LCD Module and Server Status Information
The tables in this section describe status items that are displayed on the front panel LCD for each type of component in the
chassis.
Table 44. CMC Status
Item Description
Name/Location Example: CMC1, CMC2.
No Errors If there are no errors, No Errors is displayed. Else, error messages are
listed where critical ones are first listed, and then the warning-related.
Firmware Version Only displays on an active CMC. Displays Standby for the standby CMC.
IP4 <enabled, disabled> Displays current IPv4 enabled state only on an active CMC.
IP4 Address: <address, acquiring> Only displays if IPv4 is enabled only on an active CMC.
IP6 <enabled, disabled> Displays current IPv6 enabled state only on an active CMC.
IP6 Local Address: <address> Only displays if IPv6 is enabled only on an active CMC.
MAC: <address> Displays the CMC's MAC address.
Table 45. Chassis or Enclosure Status
Item Description
User Define Name Example: Dell Rack System. This can be configured using the CMC CLI or Web interface.
Error Messages If there are no errors, No Errors is displayed. Else, error messages are listed where critical
ones are first listed, and then the warning-related.
Model Number Example "PowerEdgeM1000".
Power Consumption Current power consumption in watts.
Peak Power Peak power consumed in watts.