Users Guide

Table Of Contents
Viewing Enclosure Status and Attributes
CMC displays the health of the enclosure based on the physical components. Data of the enclosures attached to shared storage
is displayed in CMC, but the external enclosures attached to few PCIe cards are not displayed. You must have CMC Login
privileges to view the status and attributes of the enclosures.
Viewing Enclosure Status and Attributes Using Web Interface
To view the status and attributes of the enclosure:
Click Chassis Overview Storage Enclosures Properties. The Enclosures page provides the health status of the
enclosures in the chassis. For more information, see the CMC Online Help.
Viewing Status and Attributes of Enclosure Using RACADM
To view the status of the enclosure, use racadm raid get enclosures o p Status command.
To view the attributes of the enclosure, use racadm raid get enclosures o command.
For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide
available at dell.com/support/manuals.
Reporting up to two Enclosures per Connector
Each External Shared PERC 8 card supports up to two enclosures per connector. However, there are two different
configurations with different restrictions. In a single PERC (non-fault tolerant) configuration you can connect up to two
enclosures per card. Because of redundant cabling, a Fault Tolerant External Shared PERC 8 card solution supports up to two
enclosures per fault tolerant pair.
If more than two enclosures are detected on any connector, a warning message is logged to the chassis log. This affects chassis
health and provides an active alert or chassis log entry.
Setting Asset Tag and Asset Name of the Enclosure
To identify the enclosures, set the asset name and asset tag of the enclosures.
NOTE:
Error is displayed if you enter an invalid value.
Initially the value which is saved in the firmware is displayed.
You must have Chassis Configuration Privileges to set asset tag and asset name of the enclosure.
You can set Asset Tag and Asset Name only for external enclosures.
Setting Asset Tag and Asset Name of the Enclosure Using Web Interface
To set the asset tag and asset name of the enclosure, click Chassis Overview Storage Enclosures Setup. Type the
Asset Tag and Asset Name in the appropriate fields, and then click Apply. For more information, see the CMC Online Help.
Setting Asset Tag and Asset Name of the Enclosure Using RACADM
To set asset tag of the enclosure, use racadm raid set enclosures:
Enclosure.External.0-0:RAID.ChassisSlot.5-1 p AssetTag <value> command.
To set asset name of the enclosure, use racadm raid set enclosures:
Enclosure.External.0-0:RAID.ChassisSlot.5-1 p AssetName <value> command.
For more information, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide
available at dell.com/support/manuals.
Managing Chassis Storage
189