For example, to set the priority level to 1 for the server in slot 4, type the following command:
racadm config -g cfgServerInfo -o cfgServerPriority -i 4 1
Viewing Power Consumption Status
CMC provides the actual input power consumption for the entire system.
Viewing Power Consumption Status Using CMC Web Interface
In the left pane, click Chassis Overview > Power > Power Monitoring. The Power Monitoring page displays the power
health, system power status, real-time power statistics, and real-time energy statistics. For more information, see the Online
Help.
NOTE: You can also view the power redundancy status under Power Supplies.
Viewing Power Consumption Status Using RACADM
To view power consumption status using RACADM:
Open a serial/Telnet/SSH text console to CMC, log in, and type:
racadm getpminfo
AC Power Recovery
If the AC power supply of a system is disrupted, the chassis is restored to the previous power state before the AC power loss.
The restoration to the previous power state is the default behavior. The following factors could cause the disruption:
power outage
power cables pulled from the power supply units (PSUs)
power distribution unit (PDU) outage
If the Budget/Redundancy Configuration > Disable AC Power Recovery option is selected, the chassis remains powered
off after the AC recovery.
In case, the blade servers are not configured to automatic power-up, you may have to power them on manually.
Viewing Power Budget Status Using CMC Web
Interface
To view power budget status using CMC Web interface, in the left pane go to Chassis Overview and click Power > Budget
Status. The Power Budget Status page displays the system power policy configuration, power budget details, budget
allocated for server modules, and chassis power supply details. For more information, see the Online Help.
Viewing Power Budget Status Using RACADM
Open a serial/Telnet/SSH text console to CMC, log in, and type:
racadm getpbinfo
For more information about getpbinfo, including output details, see the getpbinfo command section in the Chassis
Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide.
166