Users Guide
• Monitor — This mode enables you to monitor the chassis components but you cannot perform any rmware update through
iDRAC, OS, iDRAC RACADM proxy, or Lifecycle Controller.
• Manage and Monitor — This mode enables you to monitor the chassis components and update the CMC rmware using DUP
through iDRAC, OS, iDRAC RACADM, or Lifecycle Controller.
Conguring chassis management at server mode using
RACADM
To enable the Chassis Management at server using RACADM, use the following commands:
• To disable Chassis Management at Server mode, use:
racadm config –g cfgRacTuning – cfgRacTuneChassisMgmtAtServer 0
• To change Chassis Management at Server mode to monitor, use:
racadm config –g cfgRacTuning – cfgRacTuneChassisMgmtAtServer 1
• To change Chassis Management at server mode to manage and monitor, use:
racadm config –g cfgRacTuning – cfgRacTuneChassisMgmtAtServer 2
Installing and setting up CMC 35