Release Notes
Known Issues
Dierent PCIe card device name displayed on the
iDRAC and CMC GUIs
Description PCIe card device name displayed on the iDRAC GUI and CMC GUI is not same for Broadcom/Qlogic 10G card.
Resolution Refer to the iDRAC GUI, it is accurate and current.
Versions/Systems
aected
None
Error occurs while importing CMC conguration le
Description An error occurs while importing CMC conguration le using local or remote RACADM.
Resolution This issue occurs when IPv6 is enabled or disabled from the conguration le. Enable or disable IPv6 using the
command, racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0.
Versions/Systems
aected
CMC for PowerEdge FX2 1.10 or later
Value of power available for server power on increases
after PSU failure
Description
The value of "Power Available for Server Power-on” can increase after PSU failure and recovery, without any
changes to the underlying chassis hardware components.
Resolution
For actual power consumption of the chassis, in the CMC GUI, go to the Chassis Overview > Power > Power
Monitoring > System Input Power .
Versions/Systems
aected
All versions of FX2/FXs
Unable to view chassis logs from remote RACADM
Description
Unable to view chassis logs from remote RACADM
Resolution None
Use rmware RACADM instead, to view the chassis logs.
Versions/Systems
aected
All CMC versions for PowerEdge FX2 2.10 using OM 911 and later.
Tracking number 109003
8
14 Known Issues