Users Guide

missing properties into the configuration file after running the getconfig -f command. This is true for all the RACADM–indexed
groups.
This is the list of the indexed groups that exhibit this behavior and their corresponding key properties:
cfgUserAdmin — cfgUserAdminUserName
cfgEmailAlert — cfgEmailAlertAddress
cfgTraps — cfgTrapsAlertDestIPAddr
cfgStandardSchema — cfgSSADRoleGroupName
cfgServerInfo — cfgServerBmcMacAddress
Modifying the CMC IP Address
When you modify the CMC IP address in the configuration file, remove all unnecessary <variable> = <value> entries. Only the
actual variable group’s label with [ and ] remains, including the two <variable> = <value> entries pertaining to the IP address
change.
Example:
#
# Object Group "cfgLanNetworking"
#
[cfgLanNetworking]
cfgNicIpAddress=10.35.10.110
cfgNicGateway=10.35.10.1
This file is updated as follows:
#
# Object Group "cfgLanNetworking"
#
[cfgLanNetworking]
cfgNicIpAddress=10.35.9.143
# comment, the rest of this line is ignored
cfgNicGateway=10.35.9.1
The command racadm config -f <myfile>.cfg parses the file and identifies any errors by line number. A correct file updates the
proper entries. Additionally, you can use the same getconfig command from the previous example to confirm the update.
Use this file to download company-wide changes or to configure new systems over the network with the command, racadm
getconfig -f <myfile>.cfg.
NOTE:
Anchor
is a reserved word and should not be used in the .cfg file.
Configuring Multiple CMCs through RACADM
Using Chassis Configuration Profiles
By using chassis configuration profiles, you can export the chassis configuration profiles as an XML file and import it to another chassis.
Use RACADM get command for export operation and set command for import operation.
NOTE: By default, the export is done as clone type. You can use the –—clone to get the clone type profile in XML file.
You can export chassis profiles (XML files) from CMC to the network share or to a local management station and import chassis profiles
(XML files) from the network share or from a local management station.
The import and export operation to and from the network share can be done through local RACADM as well as remote RACADM.
Whereas, the import and export operation to and from the local management can be done only through remote RACADM interface.
Exporting Chassis Configuration profiles
You can export chassis configuration profiles to network share by using the get command.
Configuring CMC