Users Guide

To display the NDC or LOM MAC address, use the following RACADM command:
racadm getmacaddress
To display the MAC address for chassis, use the following RACADM command:
racadm getmacaddress -m chassis
To display the iSCSI MAC addresses for all servers, use the following RACADM command:
racadm getmacaddress -t iscsi
To display the iSCSI MAC for a specific server, use the following RACADM command:
racadm getmacaddress [-m <module> [-x]] [-t iscsi]
To display the user-defined MAC and WWN address, use the following RACADM command:
racadm getmacaddress -c io-identity
racadm getmacaddress -c io-identity -m server -2
To display the console assigned MAC/WWN of all LOMs or mezzanine cards, use the following RACADM command:
racadm getmacaddress -c all
To display the chassis assigned WWN/MAC address, use the following RACADM command:
racadm getmacaddress -c flexaddress
To display the MAC/WWN addresses for all LOMs or mezzanine cards, use the following RACADM command:
racadm getmacaddress -c factory
To display the Ethernet and iSCSI MAC/WWN addresses for all iDRAC/LOMs/mezzanine cards, use the following RACADM command:
racadm getmacaddress -a
For more information on the getflexaddr and getmacaddress subcommand, see the Chassis Management Controller for
PowerEdge VRTX RACADM Command Line Reference Guide.
Command Messages
The following table lists the RACADM commands and output for common FlexAddress situations.
Table 28. FlexAddress Commands and Output
Situation Command Output
SD card in the active CMC module is bound
to another service tag.
$racadm featurecard -s
The feature card inserted is
valid and contains the
following feature(s)
FlexAddress: bound to another
chassis, svctag = <Service tag
Number> SD card SN = <Valid
flex address serial number>
SD card in the active CMC module that is
bound to the same service tag.
$racadm featurecard -s
The feature card inserted is
valid and contains the
following feature(s)
FlexAddress: bound
146 Using FlexAddress and FlexAdress Plus