Release Notes

Description
VLAN settings from the leader chassis are not propagating to member chassis.
Resolution
None
Versions/Systems Affected
All CMC versions including CMC 2.01 for Dell PowerEdge VRTX.
Issue 4:
Description
After Shared PERC8 controller update, RAID related operations may take longer to report status.
Resolution
Wait for the operation status to report.
Versions/Systems Affected
CMC version 2.01 for Dell PowerEdge VRTX.
Issue 5 (234547):
Description
An error occurs while importing CMC configuration file using local racadm or remote racadm.
Resolution
This issue occurs when IPv6 is enabled or disabled from the configuration file. Enable or disable IPv6
using the command
“racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0”.
Versions/Systems Affected
CMC Version 2.0 for Dell PowerEdge VRTX
Issue 6:
Description
Flash Media Status showing as "Version mismatch", when changeover the CMC or upgrade the CMC
Resolution
If chassis profile backup restore is performed on CMC-1 (active CMC) and changeover to CMC-2 (standby)
is done, there will be a version mismatch in the chassis configuration profile for extended storage in
CMC-2 after the changeover. The mismatch can be prevented by saving any server profile on CMC-1
before changing over to CMC-2. In case of version mismatch on CMC-2 after the changeover, the
changeover to CMC-1 can be performed to resolve the issue.
Versions/Systems Affected
All CMC versions including CMC 2.1 for Dell PowerEdge VRTX
Limitations
Issue 1 (191858):
Description
The Server Profile page hangs after applying a profile to multiple servers.
Resolution
Do not perform any operations in GUI until the pop-up message is displayed in the GUI.
Dell - Internal Use - Confidential