Reference Guide
• Get Power Status on iDRAC
racadm serveraction powerstatus
Server Power Status: ON
• Reseat server 2 on CMC
$ racadm serveraction -m server-2 reseat -f
Server power operation successful
• Explanation of Support
iDRAC needs to support graceful shutdown
The support of address individual blades is expected on the CMC
set
Description
Import saved CMC configuration or CMC Event Filter configuration from a file.
NOTE: If CMC is not in the network, you cannot import the chassis
configuration profile from a remote network share with proxy using the set
command. But, you can import the chassis configuration profile from the
local management station.
Synopsis
racadm -r <CMC IP> -u <CMC username> -p <CMC password> set -
f <filename>
racadm -r <CMC IP> -u <CMC username> -p <CMC password> set -
f <filename> -t xml
racadm set -f <filename> -t xml -u <username> -p <password> -
l <CIFS share>
racadm set -f <filename> -t xml -l <NFS share>
Input
• -f: import CMC configuration or CMC event filter from a file.
• -u: username of the remote share from where the file must be imported.
• -p: password for the remote share from where the file must be imported.
• -l: network share location from where the file must be imported.
• -t: specify the file type to be imported. The valid value is “xml”. This option is
case-sensitive.
Example
• Configure event filter configurations from a configuration file using remote
racadm
racadm -r 192.168.0.120 -u <username> -p <password> set -
f file.txt
• Configure a CMC from an XML configuration file on a local share using
remote racadm
racadm -r 192.168.0.120 -u <username> -p <password> set -
f myfile.xml -t xml
• Configure a CMC from an XML configuration file on a remote CIFS share
racadm set -f myfile.xml -t xml -u myuser -p mypass -l //
192.168.0.0/myshare
• Configure a CMC from an XML configuration file on a remote NFS share
racadm set -f myfile.xml -t xml -l 192.168.0.0:/myshare
97