Reference Guide
0-0:RAID.ChassisIntegrated.1-1 -assign yes -type ghs
racadm raid hotspare:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1 -assign yes -type dhs -
vdkey:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
cancelinit
Description
Stops an initialization operation on the specified virtual drive.
Synopsis
racadm raid cancelinit:<VD FQDD> {-current | -pending}
Input
• –current <optional>: Immediately performs the configuration operation.
NOTE: If this requires the system to restart, the system will be restarted.
• –pending: Save the configuration change for a later application. You can use a
combination of the –pending and –current flags on multiple commands to reduce
the possible number of system rerestartts.
Example
racadm raid cancelinit:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
cancelrebuild
Description
Stops a rebuild on a specified physical disk drive.
Synopsis
racadm raid cancelrebuild:<PD FQDD> {-current | -pending}
Input
• –current <optional>: Performs the configuration right now.
NOTE: If this requires the system to restart, the system is restarted.
• –pending: Save the configuration change for a later application. You can use a
combination of the –pending and –current flags on multiple commands to reduce
the possible number of system rerestarts.
Example
racadm raid cancelrebuild:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
assignva
Description
Assigns a virtual disk to one or more virtual adapters.
NOTE: You can assign virtual disk to multiple virtual adapters when you select the
mode of assignment as multiple.
Synopsis
racadm raid assignva:<VA FQDD> -vdkey:<VD FQDD> -accesspolicy {na
| rw} -assignpolicy {single | multiple}{-current | -pending}
Input
• –current <optional>: Performs the configuration right now.
NOTE: If this requires the system to reboot, the system will reboot then.
• –pending: Save the configuration change for a later application. You can use a
combination of the –pending and –current flags on multiple commands to reduce
the possible number of system restarts.
• –assignpolicy {single|multiple}: Uses the specified assign policy to determine if the
Virtual Disk can be assigned to multiple Virtual Adapters.
90