Reference Guide

Example
racadm raid exportlog:RAID.ChassisIntegrated.1-1 -l <CIFS or NFS
share> -u<username> -p <password> [-f <filename>]
forceonline
Description
Forces the RAID Controller to make the specified drive online. This operation may result
in obsolete or corrupted data, and should only be attempted in cases where a rebuild
operation has failed or is not applicable.
Synopsis
racadm raid forceonline:<PD FQDD> {current|pending}
Input
–current <optional>: Performs the configuration right now.
NOTE: If this requires the system to reboot, then the system is rebooted.
–pending: Save the configuration change for a later application. You can use a
combination of the –pending and –current flags on multiple commands to reduce
the possible number of system reboots.
Example
racadm raid forceonline:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
get controllers
Description The command lists all RAID controllers detected in the system and their properties.
NOTE: To use this subcommand, you must have the CMC Login User privilege.
Synopsis
raid get controllers -o
Input
-o — The -o is used to display the fault-tolerant status of a RAID controller.
Example Sample output of a CMC in which either fault-tolerant mode is not available or is
not enabled.
RAID.ChassisIntegrated.1-1
Status = Ok
RollupStatus = Ok
Name = Shared PERC8 (Embedded)
FirmwareVersion = 23.8.3-0027
DriverVersion = 06.802.11.00
RebuildRate = 30 %
BgiRate = 35 %
CheckConsistencyRate = 40 %
ReconstructRate = 30 %
PatrolReadRate = 30 %
PatrolReadMode = Manual
PatrolReadState = Stopped
CheckConsistencyMode = Stop On Error
LoadBalanceSetting = Disabled
CopybackMode = OFF
PreservedCache = Not Present
CacheMemorySize = 1024 MB
PersistHotspare = Disabled
SpindownUnconfiguredDrives = Disabled
SpindownHotspare = Disabled
Timeintervalforspindown = 30 (Minutes)
81