Reference Guide
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
• racadm getversion
• racadm getversion [-b | -c] [-m <module>]
• racadm getversion -l [-m <module>] [-f <filter>]
Input
NOTE: The -b, -c and -l options are not available for CMC modules.
NOTE: The -l option requires that the Lifecycle Controller service is enabled on the
servers. For version information, see the RACADM Readme available at dell.com/
support/manuals.
• (none) — Displays the version information for all targets or devices.
<Server> <iDRAC Version> <Blade Type> <Gen>
<
Updatable>
server-2 2.20.20.20 (41) PowerEdge
M830 (VRTX) iDRAC 8 y
<Switch> <Model Name> <HW Version> <FW
Version>
switch-1 R1-2401 VRTX 1Gb Switch Module
A01 2.0.0.39
<CMC> <CMC Version> <Updatable>
cmc-1
2.04.A00.201504150025 Y
cmc-2
2.04.A00.201504150025 Y
<Chassis Infrastructure> <FW Version> <FQDD>
Main Board 2.2.A00.201506292078
System.Chassis.1#Infrastructure.1
<Storage Controller> <FW Version> <FQDD>
Shared PERC8
23.13.06.0011 RAID.ChassisIntegrated.1-1
<Storage Enclosure> <FW Version> <FQDD>
VRTX3.5x12 0:0 2.00
Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
<Physical Disk> <FW Version> <FQDD>
Physical Disk 0:0:0 ES68 Disk.Bay.
0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
Physical Disk 0:0:1
ES68 Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
• -b - Displays the server's current BIOS version (default is iDRAC version).
• -c - Displays the server's current CPLD version.
• -l - Displays the firmware versions Lifecycle Controller components.
• -f <filter> - Filters the components. Must be used with -1 and be one of the
following values:
– bios: BIOS
– idrac: iDRAC
– usc: Unified Server Configurator (Lifecycle Controller)
– diag: 32-bit Diagnostics
64