Reference Guide
To use this subcommand, you must have CMC
Login User privilege.
Synopsis
racadm getredundancymode
Example
racadm getredundancymode
Redundant
getsel
Description Displays all sensor event log entries in the DRAC.
Synopsis
• racadm getsel -i [-A]
• racadm getsel [-s <start>] [-c <count>] [-A] [-o] [-E] [-R] [--more]
If no arguments are specified, the entire log is displayed.
Input
• -A — Specifies output with no display headers or labels.
• -c — Provides the number of records to be displayed.
• -o — Displays each entry in the SEL in a single line.
• -s — Specifies the starting record used for the display.
• -E — Displays RAW SEL data with the other data for each entry.
• -R — Displays only RAW SEL data for each entry.
• -i — Displays the number of entries in the SEL.
• --more — Displays one screen at a time and prompts the user to continue (similar to
the UNIX more command.)
NOTE: The -A, -E, -o, and -R options are deprecated.
Output
Record: 12
Date/Time: 11/20/2011 14:19:34
Source: system
Severity: Ok
Description: C: boot completed.
Example
racadm getsel
getsensorinfo
Description
Displays status of chassis sensors.
NOTE: To use this subcommand, you must have CMC Login User
privilege.
Synopsis
racadm getsensorinfo
58